Send Message

Industrial Biomass Steam Boiler , Waste Wood Boiler Single Cylinder Waterproof Shells

Negotiable
MOQ
Negotiable
Price
Industrial Biomass Steam Boiler , Waste Wood Boiler Single Cylinder Waterproof Shells
Features Gallery Product Description Request A Quote
Features
Specifications
Product Name: Series Rice Husk Wood Chip Burning Biomass Fired Steam Boiler
Design Fuel: Biomass, Straw, Wood, Coal
Output: Steam
Style: Historical
Condition: New
Pressure: 1.25/1.6Mpa
Dimension: Depends
After-sales Service Provided: Engineers Available To Service Machinery Overseas
Feed Water Temperature: 20℃
Color: Depends
High Light:

industrial biomass boiler

,

biomass fired boiler

Basic Infomation
Place of Origin: CHINA
Brand Name: OEM
Certification: CE Certification
Model Number: OEM
Payment & Shipping Terms
Packaging Details: Carton, pallet, wooden case or according to customer's package requirements
Delivery Time: 30 working days
Payment Terms: 30% deposit + 70% T/T before shipping
Supply Ability: 20 sets per month
Product Description

Product Description     

                                                     Series Biomass Fired Steam Boiler​                                                                                                                                                              

New sewing machines are single-cylinder boilers with waterproof shells and the fuel equipment is a deep chain. The water wall on the left and right sides of the stove has a bright heating level.

The lower part of the sewing pipe is adopting the new technology: Two wings of the stove body are convex heat and the heat level of the stainless steel conveyor belt (57 × 3) is located on the drum. The fire wall is made of resistant concrete and has three dimensions outside the pots.

 

 

Product Features

1. Easy install:

Typically, a boiler is a fast-moving plant that is convenient for transportation and installation, which shortens the construction time, saves installation costs, and allows for timely commissioning of the boiler.

 

2. Reliable action:

The design of the boiler heating system is reasonable, the water flow is stable and the thermal safety level is cooled in a timely manner to ensure the safety of the boiler.

 

3. Appropriate maintenance and repairs:

The pot drum is provided with an inspection hole to access the inspection. Opening a smoking box in front of the fire is convenient and the staff can easily and clearly inspect and create the right conditions for proper treatment.

 

4. Complete burn:

With secondary air conditioning and a smoother design, the fuel is fully burned to eliminate black smoke.

 

5. Effective golf:

The fire accepts dual ventilation and is naturally prevented by purification technology from the front of the pots to avoid airflow, oil leakage, irregular ventilation, proper operation and visible advantages over a simple grinder.

 

6. Convenient Cleaning:

Large amount of ash combustion can be formed in the fire that can effectively remove dust from the soil, prevent work errors, reduce heat efficiency by collecting ash and provide a stable boiler load.

 

 

 

Technical Parameters 

Main Technical Parameters of  Biomass Series Steam Boiler

 

Steam Capacity t/h 1 2 3 4 6 8 10
Working Pressure MPa 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6 1.25/1.6
Steam Temperature 193/204 193/204 193/204 193/204 193/204 193/204 193/204
Feed Water Temperature 20 20 20 20 20 20 60
Thermal Efficiency / ≥82%
Fuel / Biomass particles
Fuel Consumption Kg/h 176.6 352.3 571 522 1044 1396.5 1743.3
Heating area m2 39.82 86 120.2 174.32 220.6 317 409
Grate area m2 1.97 3.2 4.8 5.5 7.04 11.7 13.6
Power consumption Kw 18 26 31.5 34 62.4 76.4 87.2
water volume m3 4.5 4.68 5.9 6.3 11 13.8 16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.

 

External and Interface Dimension of  Biomass steam boiler                                                                                                                                                          

Steam Capacity t/h 1 2 3 4 6 8 10

Transport Dimension

 

L mm 5100 6140 6330 6880 7290 7800 8500
W mm 2200 2600 2700 2700 3190 3400 3400
H mm 2900 3300 3300 3300 3700 3700 3700
Mainframe Transport Weight / t 15 18 24 27 31 33 41
Main Steam Valve Pipe Diameter DN mm 65 80 100 100 125 150 150
Feed Water Valve DN mm 40 40 40 40 50 50 50
Safety Valve Diameter DN mm 2*40 2*50 2*50 2*50 50/80 2*80 2*80
Drain Valve Pipe Diameter DN mm 3*40 3*40 3*40 3*40 3*40 3*40 3*40
Chimney Diameter φ mm 280 350 410 410 530 720 750

Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.

 

Recommended Products
Get in touch with us
Contact Person : furnacess
Tel : + 86 17733330123
Fax : 86-10-34242423-33
Characters Remaining(20/3000)