Product Discription
The furnace plate is 1600 mm. On the side of the furnace body, there is a water cooling wall, a radioactive water heating surface. _below 1600. Important. The technology of dissolving furnaces is introduced into the process of.
Body configuration, water-cooled wall board 160, internal dissolution 160, 1600, 1600*14, police 57*3, 159*6, 133*6, 130, before and after police use, high burning rate.
Product Features
1. Easy installation:
Boilers are usually equipped with fast loading equipment, which facilitates the transportation and installation of equipment, greatly shortens the construction cycle and provides convenience for users.
2. Operational reliability:
The boiler is well equipped, the water circulation is smooth, and the cooling work is carried out on time.
3. Maintenance facilities:
The drawer in front of the boiler is easy to open, and the staff can easily and clearly check, these are good conditions for proper processing.
4. Total combustion
Reasonable arrangement of furnace lining, smooth water circulation, timely cooling.
5. Longevity and durability:
The boiler has good professional design, advanced production facilities and strict quality control. Every new boiler has quality assurance.
6. low noise level:
Boilers have low greenhouse gas emissions, efficient scrubbers and low noise fans at the tail, which meet the national environmental requirements.
Technical Parameters
Main Technical Parameters of Biomass Hot Water Boiler
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 |
Outlet Pressure | MPa | 1.0 | 1.0 | 1.0 | 1.0 | 1.0/1.25 | 1.0/1.25 | 1.0/1.25 |
Outlet Temperature | ℃ | 95 | 95 | 95 | 95 | 95/115 | 95/115 | 95/115 |
Feed Water Temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Thermal Efficiency | / | ≥83% | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 174.3 | 348.6 | 517 | 687.2 | 1024 | 1374.3 | 1708 |
Heating area | m2 | 35.2 | 79.8 | 114.2 | 168 | 207.6 | 300.5 | 391 |
Grate area | m2 | 1.97 | 3.2 | 4.8 | 5.5 | 7.04 | 11.7 | 13.6 |
Power consumption | Kw | 18 | 26 | 31.5 | 34 | 62.4 | 76.4 | 87.2 |
water volume | m3 | 5.1 | 5.58 | 6.95 | 9.3 | 14 | 17.8 | 20.5 |
Note: the fuel consumption in the table is calculated on the basis of the low calorific value of biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
Thermal Power | MW | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7 | |
Transport Dimension
|
L | mm | 5100 | 6140 | 6330 | 6880 | 7290 | 7800 | 8500 |
W | mm | 2200 | 2600 | 2700 | 2700 | 3190 | 3400 | 3400 | |
H | mm | 2900 | 3300 | 3300 | 3300 | 3700 | 3700 | 3700 | |
Mainframe Transport Weight | / | t | 15 | 18 | 24 | 27 | 31 | 33 | 41 |
Outlet Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Feed Water Valve | DN | mm | 80 | 100 | 125 | 125 | 150 | 200 | 200 |
Safety Valve Diameter | DN | mm | 1*32 | 1*50 | 2*40 | 2*40 | 2*50 | 2*50 | 2*50/80 |
Drain Valve Pipe Diameter | DN | mm | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.