Product Description
SeriesBiomass Steam Boiler
The new series steam boiler is a single steam cooling tube boiler, which is used for the combustion equipment of chain boiler row. The cooling walls on the left and right sides of the boiler are hot surfaces. Radiation.
A new cross-arrangement method is adopted at the lower part of the boiler tube. Both sides of the boiler body are convective hot surfaces, and the boiler tube includes convective hot surfaces. Thermal stability is provided for three maintenance boxes outside the boiler.
Product Features
1. Easy installation:
Boilers are usually equipped with fast installation equipment to facilitate the transport and installation of equipment, greatly reduce the construction cycle, and provide a comfortable environment for users.
2. Business failure:
Full-equipped boiler, free water circulation, timely cooling.
3. Maintenance equipment:
It is easy to open the drawer in front of the boiler. The staff can easily and clearly check the drawer. This is a good working condition.
4. Total Combustion:
Reasonable coating system, water circulation is fluid, rapid cooling.
5. Life and Sustainability:
Refrigerator is an excellent refrigeration plant, advanced production equipment, strict quality control. Every new boiler has quality assurance.
6. Low noise:
Boilers are characterized by low-temperature greenhouse gas emissions, high-efficiency washing machines, low noise, etc. to meet national environmental requirements.
Technical Parameters
Main Technical Parameters of Biomass Series Steam Boiler
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 |
Working Pressure | MPa | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Steam Temperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 60 |
Thermal Efficiency | / | ≥82% | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 176.6 | 352.3 | 571 | 522 | 1044 | 1396.5 | 1743.3 |
Heating area | m2 | 39.82 | 86 | 120.2 | 174.32 | 220.6 | 317 | 409 |
Grate area | m2 | 1.97 | 3.2 | 4.8 | 5.5 | 7.04 | 11.7 | 13.6 |
Power consumption | Kw | 18 | 26 | 31.5 | 34 | 62.4 | 76.4 | 87.2 |
water volume | m3 | 4.5 | 4.68 | 5.9 | 6.3 | 11 | 13.8 | 16.5 |
Note:biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
External and Interface Dimension of Biomass steam boiler
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
Transport Dimension
|
L | mm | 5100 | 6140 | 6330 | 6880 | 7290 | 7800 | 8500 |
W | mm | 2200 | 2600 | 2700 | 2700 | 3190 | 3400 | 3400 | |
H | mm | 2900 | 3300 | 3300 | 3300 | 3700 | 3700 | 3700 | |
Mainframe Transport Weight | / | t | 15 | 18 | 24 | 27 | 31 | 33 | 41 |
Main Steam Valve Pipe Diameter | DN | mm | 65 | 80 | 100 | 100 | 125 | 150 | 150 |
Feed Water Valve | DN | mm | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
Safety Valve Diameter | DN | mm | 2*40 | 2*50 | 2*50 | 2*50 | 50/80 | 2*80 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.