Induction Heating High Temperature Sintering Furnace Easy Operate
Main Specifications
Maximum operating temperature: 2450 ° C
Common temperature: 2400 ° C
High temperature zone volume: 200-2000mm × 300-4000mm; or square
Heating method: induction heating
Working gas in the furnace: nitrogen argon
Temperature uniformity: ≤ ± 10 ° C
Temperature control: PID intelligent program control and manual control
Temperature control accuracy: ±1 °C
According to the needs of the sintering process time, multiple electric furnaces can be configured with a single power supply, and the individual furnaces are respectively energized, cooled, and cooled to achieve continuous operation.
Temperature measurement: WRe5/26 thermocouple (0-1700 °C) + US RATEK dual colorimetric infrared thermometer (1000-3200 ° C); US RATEK monochrome infrared thermometer (300-1100 ° C) + US RATEK double ratio Color infrared thermometer (1000-3200 ° C)
The device adopts multi-channel data acquisition and displays and operates on the man-machine interface. The operating parameters are clear at a glance, easy to operate and low in labor intensity.
The device has data logging and dumping functions, and the data can be viewed through historical curves and can be transferred to removable storage media.
Application:
Vacuum Sintering Furnaces Were Suited For Kinds Industiral Ceramics, Cemented Carbide, Graphite Purification,Magnet Material & Rare Refractory Metal. Also Good At Heat Treatment Of Permanet Magnet Material & Diamond Tools.
Product Model Specification | |
Volume (L) | 350 |
Rated Temperature (°C) | 2400 |
Limit Temperature (°C) | 2450 |
Effective Heating Zone (Mm) | 500X500X1400 |
Power (KW) | 250 |
Frequency (HZ) | 1000 |
Temperature Control Method | Japan Island Electric Thermostat |
Heating Method | Induction heating |
Vacuum System | Rotary vane vacuum pump or spool type vacuum pump + Roots vacuum pump (vacuum degree requirement plus oil distribution pump) |
Sintering Atmosphere | N2, Ar2 and other gases |
Rated Power Supply Voltage (V) | 380 |
Rated Heating Voltage (V) | According to the design, configure the transformer |
Vacuum Limit (Pa) | 6X10ˉ2 (vacuum cold state) |