Product Description
Series Biomass Fired Steam Boiler
The new is a cylinder designed with clothes and bridges. The walls found on the left and right sides of the boiler have a distinct fire balance.
A new method is used under the seam: the two wings warm the entire body, but the mold has a stainless steel heater (57 x 3). The fire extinguisher protects the object and has three outside sides.
Product Features
1. Easy to install:
Of course, high speed compressors are easy to transport and install, which reduces construction time, saves installation costs, and can effectively transport fireplaces.
2. Trust investment:
The heating system uses a water retention system and a heating system for accurate and accurate design to ensure air safety.
3. Repair and maintenance:
Drums have the same material for analysis. It is recommended to open the fuse in front of the kitchen so that employees can easily and effectively monitor and create appropriate medical conditions.
4. Rejection:
The oil is hot enough to remove black smoke from the secondary air line and the constant engine.
5. Golf:
The air is extracted from any vacuum cleaner and fixed to the surface to prevent water leakage, fuel pumps, air resistance, effectiveness and efficiency beyond the benefit of simple air.
6. dried straw:
In a fire, combustion produces a high level of combustion, removes dust from the ground, prevents operating errors, reduces heat and ash, and increases the risk of burns.
Technical Parameters
Main Technical Parameters of Biomass Series Steam Boiler
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 |
Working Pressure | MPa | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 |
Steam Temperature | ℃ | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 | 193/204 |
Feed Water Temperature | ℃ | 20 | 20 | 20 | 20 | 20 | 20 | 60 |
Thermal Efficiency | / | ≥82% | ||||||
Fuel | / | Biomass particles | ||||||
Fuel Consumption | Kg/h | 176.6 | 352.3 | 571 | 522 | 1044 | 1396.5 | 1743.3 |
Heating area | m2 | 39.82 | 86 | 120.2 | 174.32 | 220.6 | 317 | 409 |
Grate area | m2 | 1.97 | 3.2 | 4.8 | 5.5 | 7.04 | 11.7 | 13.6 |
Power consumption | Kw | 18 | 26 | 31.5 | 34 | 62.4 | 76.4 | 87.2 |
water volume | m3 | 4.5 | 4.68 | 5.9 | 6.3 | 11 | 13.8 | 16.5 |
Note:biomass particles 17084KJ/Kg (4085Kcal/Kg). If the low calorific value of biomass fuel is larger than this value, the corresponding fuel consumption will be more economical than the value in the table.
External and Interface Dimension of Biomass steam boiler
Steam Capacity | t/h | 1 | 2 | 3 | 4 | 6 | 8 | 10 | |
Transport Dimension
|
L | mm | 5100 | 6140 | 6330 | 6880 | 7290 | 7800 | 8500 |
W | mm | 2200 | 2600 | 2700 | 2700 | 3190 | 3400 | 3400 | |
H | mm | 2900 | 3300 | 3300 | 3300 | 3700 | 3700 | 3700 | |
Mainframe Transport Weight | / | t | 15 | 18 | 24 | 27 | 31 | 33 | 41 |
Main Steam Valve Pipe Diameter | DN | mm | 65 | 80 | 100 | 100 | 125 | 150 | 150 |
Feed Water Valve | DN | mm | 40 | 40 | 40 | 40 | 50 | 50 | 50 |
Safety Valve Diameter | DN | mm | 2*40 | 2*50 | 2*50 | 2*50 | 50/80 | 2*80 | 2*80 |
Drain Valve Pipe Diameter | DN | mm | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 | 3*40 |
Chimney Diameter | φ | mm | 280 | 350 | 410 | 410 | 530 | 720 | 750 |
Remarks: We will reserve rights to change the above mentioned data due to continuous policy transformation and product improvement.